Overview
Kerio Control 10.0.1 has been released and is available for download.
- Release date: October 28, 2026
- Build ID: 9439
Notes
- When the OpenVPN certificate authority is regenerated, every client will need to download a new profile. GFI KerioControl warns seven days before the authority expires.
- After upgrading, traffic rules that grant access to the Trusted interface group no longer cover OpenVPN clients, so add a rule for the OpenVPN interface if needed.
- If you’re upgrading from an older version, check whether an intermediate step is required before moving to 10.0.1. See the Version Update Reference Guide.
Highlights
- New appliance platform: all hardware appliances and virtual appliances now run on a Debian 12 base with the Linux 6.1 kernel (previously Debian 10 with kernel 4.19), with current versions of the system components (OpenSSH 9.2, OpenVPN, FreeRADIUS, Samba, curl, Firebird, OpenSSL 3).
- Multi-core packet processing: the firewall driver now processes traffic on all CPU cores in parallel, one packet queue per core, instead of a single queue. Throughput on multi-core appliances and virtual machines scales with the number of cores.
- New hardware: GFI KerioControl NG120, NG320, NG520, NG521 and NG720 are supported, including their port layout, LCD/LED status panels, NVMe boot and UEFI rescue media. 2.5 Gbit/s and 10 Gbit/s link speeds are supported on the new models’ ports. These models require GFI KerioControl 10.0 or later.
New features and improvements
- New VPN technology added to the GFI KerioControl VPN stack: WireGuard VPN server joins the existing GFI KerioControl VPN stack for remote-client access. Users connect with the standard WireGuard apps.
- OpenVPN: certificates are now issued with a 10-year validity (previously 1 year). An expired or otherwise unusable GFI KerioControl-generated OpenVPN certificate authority is regenerated automatically; a third-party authority that cannot be used raises a new “Unsuitable OpenVPN Authority” notification. Administrators can push specific routes to OpenVPN clients or turn off full-tunnel routing.
- High availability: outbound NAT uses the cluster’s shared (virtual) address, so translated sessions survive a failover. The virtual address is recovered after interface changes and is no longer advertised by the passive node. Each node keeps its own hostname.
- DHCP server: replies are sent from the address the client used (the cluster address or a secondary interface address) rather than always from the interface’s primary address. A passive cluster node rejects renewals from clients still bound to it, so they re-register with the active node.
- Traffic-rule statistics: now include blocked traffic, so blocking rules no longer show zero. Dashboard rule tiles list every rule with charting enabled, ranked by volume, and display in the administrator’s language.
- Configuration import: a backup taken on one appliance model can be restored on another model with at least as many Ethernet ports; interfaces follow the port labels printed on the appliance (Internet, LAN 1, LAN 2 …), so cables are reconnected to the same labels. When the administrator is connected through an Internet interface, the wizard offers to keep administration reachable after the restart by adding a traffic rule limited to the address, network or range the administrator chooses (pre-filled with their current address); the option is not offered for sessions through GFI AppManager. Backups exported by 10.0.0 from NG320, NG520 or NG521 are mapped by port position when restored on a different model; where possible, export the configuration again on 10.0.1 before replacing hardware.
- SNMP: an optional, one-time migration to stable, collision-free interface indexes is now available. Until it is enabled, indexes are unchanged; when two interfaces compute the same index, one of them is omitted from the SNMP interface table and reported in the log (previously the whole table failed to load).
Fixes
- Fixed file-descriptor exhaustion on the passive HA node and on busy installations after days of uptime, which could stop WebAdmin, VPN and IPS from accepting connections. DHCP-lease synchronization no longer re-applies the whole configuration on the passive node.
- Fixed interface statistics attributing forwarded traffic to the interface it arrived on instead of the one it left through; upload/download charts now match measured speeds.
- Fixed large TCP segments being sent with a fixed IP identification after NAT cleared the Don’t-Fragment bit, which could leave some HTTPS pages blank when GRO (Generic Receive Offload) was enabled on the Internet interface.
- Fixed Internet-side source addresses being registered as Active Hosts and consuming license seats.
- Fixed HTTPS filtering being bypassed intermittently when the TLS ClientHello spanned several TCP segments.
- Fixed bandwidth management counting routed traffic twice, which enforced lower limits than configured, and reduced its CPU overhead when rules are present.
- Fixed IPsec site-to-site tunnels not resuming traffic after the secondary Internet link returned in load-balanced configurations.
- Fixed the GFI KerioControl VPN server remaining reachable on the standby Internet link in failover mode.
- Fixed IKEv2 dial-in with server certificate and MS-CHAPv2 (native Windows, iOS and Android clients) failing with AUTH_FAILED.
- Fixed GeoIP-based traffic rules no longer matching after the WebAdmin language was changed.
- Fixed a rule keeping its “log connections” setting after its action was changed to Drop or Deny.
- Fixed statistics errors (“unable to create database”, user-ID mismatch), a crash when the statistics user was missing, and report generation failing for periods with no data.Fixed the GFI KerioControl VPN Client for macOS failing on macOS 15.4 and later when iCloud Private Relay or another VPN was active.
- Fixed engine crashes during an antivirus definition update and during repeated link changes on multi-WAN installations.
- Fixed missing scrollbars in WebAdmin in Firefox.
- After upgrading, an existing OpenVPN interface is moved out of the Trusted interface group, matching new installations.
- Fixed a failed configuration synchronization to the passive HA node leaving it with a partial or empty configuration, after which it could restart with factory defaults. The passive node now keeps its working configuration when a received file fails to load or save, and the active node is informed of the failure and retries the synchronization.
Notes for administrators
- OpenVPN client profiles: when the OpenVPN certificate authority is regenerated (see the OpenVPN item under New features and improvements), every client must download a new profile. GFI KerioControl warns seven days before the authority expires; to choose the day, delete the “OpenVPN Local Authority” certificate under Certificates and redistribute the profiles after it is regenerated.
- OpenVPN and the Trusted group: after the upgrade, traffic rules that grant access to the Trusted interface group no longer cover OpenVPN clients. Add a rule for the OpenVPN interface if needed.
- Back up before upgrading: a configuration backup taken on 10.0.1 cannot be restored on 9.6.x. If you downgrade an appliance in place, traffic rules that use GeoIP groups stop matching on 9.6.x (Allow rules stop allowing and Deny rules stop blocking), so restore your pre-upgrade 9.6.x backup after downgrading. WebAdmin now warns about this when an older image is uploaded manually. NG120, NG320, NG520, NG521 and NG720 cannot be downgraded below 10.0.
- Statistics and counts change: rule charts and dashboard tiles now include blocked traffic, forwarded traffic is counted on the outgoing interface, and Active Hosts and license-seat counts drop on installations that previously registered Internet-side addresses.
- SNMP index migration is irreversible: enabling it changes every interface index and OID once.
- Appliance boot settings: on hardware appliances and virtual appliances, deep CPU power-saving states and PCIe power management are disabled at boot, and the appliance reboots automatically if the kernel detects a hung task.
- IPsec tunnel source address: every 60 seconds GFI KerioControl checks that each established IPsec tunnel uses the local address the routing table prefers for its peer, and reconnects the tunnel if it does not. A tunnel deliberately bound to a different local address (an alias address or a policy route) reconnects every minute; use the preferred address or adjust routing.
- Intel I225/I226 network ports accept auto-negotiation only; a fixed speed or duplex can no longer be set on them, on the new appliance models and on software installations alike.